Vermont Castings Defiant
Homeowners
Installation and
Operating
Manual
For use in the
United States and Canada
SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED,
OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY OR EVEN DEATH. CONTACT LOCAL BUILDING OFFICIALS
ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN
YOUR AREA.
Do Not Discard This Manual: Retain for Future Use
2000968 1/02 Rev. 4
Defiant
Woodburning Stove
Model 1910
0968
Przeglądanie stron 0
1 2 3 4 5 6 ... 37 38

Podsumowanie treści

Strona 1 - Woodburning Stove

1Vermont Castings DefiantHomeowner’sInstallation andOperatingManualFor use in theUnited States and CanadaSAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPE

Strona 2 - All of Us at Vermont Castings

10Vermont Castings DefiantNOTE: Do not vent your Defiant into a factory-built(zero-clearance) fireplace. These appliances and theirchimneys are specif

Strona 3 - The Story of the Defiant

11Vermont Castings DefiantKeep the Stove a Safe Distance fromSurrounding MaterialsBoth a stove and its chimney connector radiateheat in all directions

Strona 4 - Specifications

12Vermont Castings DefiantDefiant Clearance Chartfor use with either a 6” or 8” flue collar/chimney connectionStove ClearanceStove InstalledParallel t

Strona 5 - Installation

13Vermont Castings DefiantTop Exit Installations, no heat shieldsDefiant Clearance Diagramsfor use with either a 6” or 8” flue collar/chimney connecti

Strona 6 - Chimney Size

14Vermont Castings DefiantDEFIANT48"(1220mm)48"(1220mm)48"(1220mm)Fig. 13 Parallel installation with rear wall pass-through, twowall s

Strona 7 - Direction

15Vermont Castings DefiantDistance from the Center of the Flue Collar to the WallThe information on this page is helpful in planning stove placement,

Strona 8 - Above the Fireplace

16Vermont Castings DefiantSet Up Your StoveCast iron stoves are heavy, and it will take two tofour people to move your Defiant into position.Wipe the

Strona 9 - Wall pass-Throughs

17Vermont Castings DefiantAssemble the Removable Insert HandleThe white removable insert handle opens and closesthe front doors. Remove after each use

Strona 10 - Floor Protection

18Vermont Castings DefiantA Damper Directs Air FlowWithin the StoveThe damper handle on the left side of the stoveoperates the damper to direct air fl

Strona 11

19Vermont Castings DefiantWARNING: FIREPLACE STOVES EQUIPPED WITHDOORS SHOULD BE OPERATED ONLY WITHDOORS FULLY OPEN OR DOORS FULLY CLOSED.IF DOORS AR

Strona 12 - Defiant Clearance Chart

2Vermont Castings DefiantThis manual describes the installation, operation, and maintenance of the Vermont Castings Defiant Model 1910catalytic-equipp

Strona 13 - Defiant Clearance Diagrams

20Vermont Castings DefiantUse the Air Control Settings that Work Best for YouNo single air control setting will fit every situation.Each installation

Strona 14 - Stove Heat Shields

21Vermont Castings DefiantIn general, the fire must be sufficiently well-established to ensure that catalytic activity is initiated.When first startin

Strona 15 - Protected Surfaces

22Vermont Castings Defiant5. Close the damper when the griddle temperaturereaches 450°F (230˚C).6. Adjust the air control for your desired heatoutpu

Strona 16 - Assembly

23Vermont Castings Defiantlikely to glow at its higher temperatures, which itreaches when the firebox is in its lower range - thecatalyst is an afterb

Strona 17 - Operation

24Vermont Castings DefiantDRAFT MANAGEMENTA stove is part of a system, which includes thechimney, the operator, the fuel, and the home. Theother part

Strona 18 - Two Ways to Add Fuel

25Vermont Castings DefiantThere should be no more than eight feet of single-wall stove pipe between the stove and a chimney;longer runs can cool the s

Strona 19

26Vermont Castings DefiantNegative PressureGood draft also depends on a supply of air to thestove; a chimney can’t pull in more air than is availablet

Strona 20 - Vermont Castings Defiant

27Vermont Castings DefiantKeep Your Stove Looking New andWorking Its BestLet the fire in the stove go out and allow the stove tocool completely before

Strona 21

28Vermont Castings DefiantCheck the Operation of thePrimary Air ShutterThe primary air shutter is at the back of the ashdrop and is visible from the b

Strona 22

29Vermont Castings DefiantThe Catalytic ElementThis wood heater contains a catalytic combustor,which needs periodic inspection and replacement forprop

Strona 23

3Vermont Castings DefiantTable of ContentsSpecifications ... 4Installation ...

Strona 24 - DRAFT MANAGEMENT

30Vermont Castings DefiantAlignment NotchesLeft WedgeBrick GuideBrick ClipBricksST556Fig. 37 Remove the bricks and the brick retainer.Right WedgeLowe

Strona 25

31Vermont Castings Defiant6. If the element is in good condition and clean, re-install it in the stove and replace the refractoryaccess cover.7. Repla

Strona 26

32Vermont Castings Defiant7. Press the gasketed part firmly against its normalmating surface to seat the gasket evenly in its channel.Close and latch

Strona 27 - Maintenance

33Vermont Castings DefiantAppendix: Catalytic CombustorIn any chemical reaction, including the combustionprocess, there are certain conditions which

Strona 28 - Adjust the Damper as Needed

34Vermont Castings DefiantAppendix: Chimney and Fireplace HazardsGeneral -A. Improper chimney height. The top of the chimneymust be at least 3 feet hi

Strona 29 - Catalytic

35Vermont Castings Defiant8513291236481626171851446474964667283436374041482711303133841067424457584366528535655961738180837476457071545679808253515588

Strona 30

36Vermont Castings DefiantItem/Model Number Part NumberDefiant (continued)13. Left Griddle Quadrant 130180714. Right Griddle Quadrant 130183216. Gridd

Strona 31 - Stove Gasket

37Vermont Castings DefiantWarrantyLimited 3 Year WarrantyThe Vermont Castings Majestic Products Company warrants thatthis woodburning stove will be fr

Strona 32 - Annual Maintenance

38Vermont Castings Defiant410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885www.majesticproducts.com • www.vermontcastings.comThe

Strona 33

4Vermont Castings DefiantSpecificationsDefiant, Model 1910Range of heat output... 10,600 to 44,400 Btu’s/hr.*Maximum heat output...

Strona 34

5Vermont Castings DefiantInstallationSAFETY NOTICE: IF YOUR DEFIANT IS NOTPROPERLY INSTALLED, A HOUSE FIRE MAYRESULT. TO REDUCE THE RISK OF FIRE,FO

Strona 35 - Defiant Woodburning Stove

6Vermont Castings DefiantWhat Kind of Chimney to UseYou must connect the Defiant to a code-approvedmasonry chimney with a flue liner, to a relined mas

Strona 36 - Defiant (continued)

7Vermont Castings DefiantAccessories to help make the connection betweenstainless steel chimney liners and your Defiant areavailable through your loca

Strona 37 - Warranty

8Vermont Castings DefiantSecuring the Single-wall Connector to aMasonry ChimneyBoth freestanding masonry chimneys and fireplacemasonry chimneys may be

Strona 38 - Majestic Products Company

9Vermont Castings DefiantIf the chimney connector in your installation entersthe chimney above a fireplace, follow all the guidelinesmentioned above f